UNIVERGE SV8100/SV8300
LED Indication
Live LED
Busy LED
(Green)
(Red)
On
On
Flash (1s)
On
Flash (1s)
On
Flash
(100ms)
Off
On
Off
Off
Flash (80ms
On/Off) x 3/
400ms Off
System Hardware Manual
Refer to the following table for maximum upgrade capacities of the
CD-4DIOPA
Table 2-4 SV8100 Maximum System Capacities – Blades on
page 2-7
Analog DID not supported in Australia.
5.5.2
Installation
The CD-4DIOPA can be installed in any universal slot.
5.5.3
LED Indications
LED indications for the CD-4DIOPA are listed in
CD-4DIOPA LED
function and LED and Operational status. Refer to
CD-4DIOPA Blade on page 6-74
blade.
Table 6-35 CD-4DIOPA LED Indications
Operation Status
System Initializing
The assignment of the unit is refused.
Trouble found during self-diagnostics.
A Channel is busy (use
Normal
another from CH1 ~ CHx).
Operation
All channels are idle.
A Channel is busy (use
Unit Busy
another from CH1 ~ CHx).
All channels are idle.
Downloading firmware.
5.5.4
Connectors
The CN2 connector provides connection to four analog DID trunk
ports, which are polarity sensitive (tip-to-tip, ring-to-ring). The OPX
circuits, however, are not polarity sensitive. The CD-4DIOPA requires
one universal slot. (Refer to
page
6-74.) If Program 10-03-01 has OPX defined, note that the
blade consumes four (4DIOPA) trunks when installed. If OPX is not
defined, then only trunks ports are consumed.
blade:
Indications. Each LED is listed with its associated
for the location of the LEDs on the
Figure 6-25 CD-4DIOPA Blade on
Issue No. 1.5
Table 6-35
Figure 6-25
Remarks
–
When you exceed the system
capacity.
When the main software
version is not matched.
–
–
–
–
–
–
6 - 75