With input voltage of 120 VAC and with full load conditions:
AC Input I: Controlling Chassis=2.19A, Expansion Chassis=2.19A,
total 4.38A
VA @ 120V: Controlling Chassis=263 VA, Expansion Chassis=
263 VA, total 526 VA KWh @ AC Input I x 120V/1000: Controlling
Chassis=0.263 KWh, Expansion Chassis=0.263 KWh, total 0.526
KWh
BTU (KWh x 3413): Controlling Chassis=1795 BTU, Expansion
Chassis=1795 BTU, total 3590 BTU
Double Pole/Neutral Fusing
(power supply fuses are located at both the L
and N side).
AC 200 V Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 240 VAC @ 15A Controlling Chassis Power
Consumption: Controlling Chassis=101 VA, Expansion
Chassis=257 VA, total 358 VA
Input Voltage: 90 VAC to 264 VAC
(Rated Voltage: 100 VAC/120 VAC/220 VAC/230 VA /240 VAC)
Frequency: 47 Hz – 63 Hz (Rated frequency: 50/60 Hz)
Phase and Wire: Single Phase 2 Line Type + PE Type
Grounding Requirements: No.14 AWG copper wire
Feeding Voltage: Digital Multiline Terminal/OPX/DID: -48V
SLT: 25mA / -28V
With input voltage of 240 VAC and with full load conditions:
AC Input I: Controlling Chassis=0.42A, Expansion Chassis=1.07A,
total 1.49A
VA @ 240V: Controlling Chassis=101 VA, Expansion Chassis=
257 VA, total 358 VA KWh @ AC Input I x 240V/1000: Controlling
Chassis=0.101 KWh, Expansion Chassis=0.257 KWh, total
0.358 KWh
BTU (KWh x 3413): Controlling Chassis=1795 BTU, Expansion
Chassis=1795 BTU, total 3590 BTU