UNIVERGE SV8100/SV8300
Terminal
PGD(2)-U( ) ADP
SMDR (RS-232C)
SMDR (LAN)
Hotel Server
Printer
6.2
System Hardware Manual
Table 3-13 Cable Length of Optional Equipment (Continued)
Cable
Kind of Cable
Pair
Twisted Pair Cable
1-pair
RS-232C Cable
(RS RVS-15S CA-F)
LAN Cable (UTP
2-pair
cable10BASE-T/
100BASE-TX)
LAN Cable (UTP
2-pair
cable10BASE-T/
100BASE-TX)
RS-232C Cable
(RS PRT-15S CA-F)
Power Requirements
A dedicated 110 VAC
located within seven feet of the chassis is required. A separate dedicated outlet
for each chassis should be installed.
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N side).
6.2.1
Power Supply Specifications
AC 100 V Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 120 VAC @ 15A Controlling Chassis
Power Consumption: Controlling Chassis=263 VA,
Expansion Chassis=263 VA, total 526 VA
Input Voltage: 90 VAC to 264 VAC
(Rated Voltage: 100 VAC/120 VAC/220 VAC/230 VA /240 VAC)
Frequency: 45 Hz – 66 Hz (Rated frequency: 50/60 Hz)
Phase and Wire: Single Phase 2 Line Type + PE Type
Grounding Requirements: No.14 AWG copper wire
Feeding Voltage: Digital Multiline Terminal/OPX/DID: -48V
SLT: 25mA / -28V
Cable Length between
SV8300 and Terminal
1968 ft (600m) with 22 AWG
2625 ft (800m) with 24 AWG
2625 ft (800m) with 26 AWG
50 ft (15m)
–
328 ft (100m) or less
328 ft (100m) or less
50 ft (15m)
–
→
120 VAC/220 VAC
→
240 VAC 50 Hz/ 60 Hz circuit
Issue No. 1.5
Remarks
–
–
–
–
–
3 - 17