Cabletron Systems SmartSwitch 6000 User Manual page 85

Frame relay module for mmac-plus
Hide thumbs Also See for SmartSwitch 6000:
Table of Contents

Advertisement

Example 1
Configuring Frame Relay
In Example 1, the primary link is between Node 1/LP 2/Port 4/DLCI 16 and Node 2/
Port 5/DLCI 18. The DLCIs should be configured as described below. (The param-
eters are described later in this chapter.) Then if the primary link goes down, a con-
nection will automatically be established between Node 1/LP 2/Port 5/DLCI 72 and
Node 2/Port 6/DLCI 19.
On Node 1, configure the following (as well as other parameters necessary for oper-
ation—this section deals only with the frame relay backup function):
1. Port Configuration (
LP: 2
RLP Port: 4
O Additional Parameters
D Configure DLCI Parameters
DLCI ID: 16
I
DLCI Backup Configuration
A Backup Group Number: 0
B Enable Backup Protocol?: N
2. Port Configuration (
LP: 2
RLP Port: 5
O Additional Parameters
D Configure DLCI Parameters
DLCI ID: 72
I
DLCI Backup Configuration
A Backup Group Number: 0
B Enable Backup Protocol?: N
3. Frame Relay Backup Groups Configuration (
Frame Relay Backup Group Number: 10
RLP: 2
next sequential number in range
Entry:
Port: 5
DLCI: 72
WaitTimer: 0–65535
ProtEnab: Y
4. Port Configuration (
LP: 2
RLP Port: 4
O Additional Parameters
D Configure DLCI Parameters
DLCI ID: 16
I
DLCI Backup Configuration
A Backup Group Number: 10
B Remote RLP: 0
C Remote Port: 5
D Remote DLCI: 18
E Switchover Timer: 0–65535
F
Switchback Timer: 0–65535
G Time to Hold Data While Waiting: 0–65535
from Main Menu):
[A], [C], [A]
from Main Menu):
[A], [C], [A]
0–9
(seconds)
from Main Menu):
[A], [C], [A]
from Main Menu):
[A], [F], [B]
(seconds)
(seconds)
(seconds)
6-3