Cabletron Systems SmartSwitch 6000 User Manual page 106

Frame relay module for mmac-plus
Hide thumbs Also See for SmartSwitch 6000:
Table of Contents

Advertisement

Connection Priority
Bandwidth Allocation Group
Encapsulation Method
Modulo
Maximum LAPB Window Size
N2 Retransmit Count
6-24
prioritizes this logical port for intra-nodal traffic; the higher the number, the higher the
priority. (This priority has no effect on traffic exiting a node.)
A priority is also configured in Node Defaults, as well as for each logical port, SNA
PU, LLC2 host, IP interface, IPX interface, SVC subscriber, and PVC connection. The
device processor in the node uses these priorities to help determine the order in which
it will process protocols.
When configuring priorities, be careful to consider the types of
traffic being routed on other connections in the node.
assigns the logical port to one of sixteen groups whose parameters regulate bandwidth
usage by outgoing traffic on the physical link. See "Configuring Bandwidth Allo-
cation Groups" on page 6-6.
is the method by which traffic over the logical port will be enveloped within frame
relay frames for transmission. The valid methods are T1.617 Annex G (a.k.a. FRF 3
and 3.1) and T1.617 RFC1490.
With Annex G, a LAPB frame is encapsulated immediately following the frame relay
header (flag, 2-byte T1.618 header, LAPB address, LAPB control, LAPB I-field
[x.25/x.75]). With RFC1490, the order is: T1.618 header, Q.922 control byte, Q.933
NLPID, 2-byte level-2 protocol ID, 2-byte level-3 protocol ID, LAPB frame.
Although it may appear that RFC1490 encapsulation uses more overhead, the number
of protocols being encapsulated are important in determining the method:
RFC1490 – The protocols will be identified on the DLCI based on their NLPIDs
and (if applicable) level-2 and level-3 headers (e.g., X.25: flag, T1.618 2-byte
header, 0x03 Q.922 control, 0x08 Q.933 NLPID, T1.617 level-2 LAPB PID
0x51 81, T1.617 level-3 PID 0x67 80, LAPB frame).
Annex G – Each protocol must be encapsulated in X.25 for transmission over a
single DLCI, because Annex G allows the DLCI to be used only by X.25. Each
protocol in would require its own X.25 virtual circuit and level-3 windows.
is the number of values used in X.25 level-2 sequenced packets. The actual packet
numbering is 0–7 for modulo 8 and 0–127 for modulo 128.
is the maximum number of sequentially numbered I-frames that can be waiting for
acknowledgment by the next station in the path. If this number is exceeded, no frames
will be transmitted until an acknowledgment is received. A larger value allows faster
throughput, but increases the number of frames that may have to be retransmitted if
there is a problem.
is the maximum number of times the node will attempt to send an I-frame after a
Retransmit Period expiration. A larger value for this parameter increases the proba-
FRX/FRM 3.3 User Guide, Rev 04

Advertisement

Table of Contents
loading

Table of Contents