Primary Alarm Output Pwd
Secondary Alarm Output ID
Secondary Alarm Output Pwd
Com. Port Thruput
Com. Port Parity:
Com. Port Stopbit
Bits per Character
Collecting Node
Configuring Node Parameters
Primary Alarm Output ID
anteed delivery to the primary output device, and output to the secondary device only
if it is available. Problems with the secondary device will not stop delivery to the
primary device.
If specifying an async port to a printer, be sure to configure the async PAD
profile (see Chapter 10) to match the line speed of the printer. (Do not con-
figure the port for
is a password that will be used with the
lecting node, the local FRX/FRM's
the collecting node's
Collecting Node Pwd
is used for a collecting node to send alarms to a second location other than that spec-
ified by the
Primary Alarm Output ID
nodes.
is a password that will be used if the
also associated with a password. If so, both passwords must match.
is the line speed (in bits per second) through the COM port:
= 110 bps
A
B
= 1200 bps
E
F
sets the parity bit, which is used to detect changes in bit structure of the data from
origin to destination:
sets 1 or 2 stopbits, which signal the end of a character.
sets the bit value at 7 or 8 per character.
is an FRX/FRM to which alarms are sent from other FRXs/FRMs. Any FRX/FRM can
be a collecting node; which FRXs/FRMs send their alarms to a collecting node is
determined by the
Primary Alarm Output ID
these must match the
Collecting Node ID
The number of FRXs/FRMs that can report to a collecting node depends on the
number of connections that can exist on the collecting node. (An FRX4000 or FRM
supports up to 512 connections; an FRX6000 supports up to 512 per RLP.) A con-
nection on a collecting node is required for each reporting device.
Do not configure a collecting node to send its alarms to another
collecting node. The alarms will be ignored, due to a format mis-
match.
of a collecting node. The alarm system is designed for guar-
.)
Autobaud
Primary Alarm Output ID
Primary Alarm Output Pwd
.
. This parameter has no function on non-collecting
Secondary Alarm Output ID
= 150 bps
= 300 bps
C
= 2400 bps
= 4800 bps
G
= None,
= Odd,
0
1
3
s and passwords of the other FRXs/FRMs;
and password of their collecting node.
. If that ID is a col-
(Password) must match
is an address that is
= 600 bps
D
= 9600 bps
H
= Even.
3-7

Advertisement

Table of Contents
loading

Table of Contents