18-24
561.
LLC Interface File Upd:LLC2IPAR.DAT
Severity:
4
Meaning:
The LLC2 Interface file has been updated.
Action:
None.
562.
LLC Host File Upd:LLC2HPAR.DAT
Severity:
4
Meaning:
The LLC2 Host file has been updated.
Action:
None.
563.
LLC LAN Card File Upd:LANPAR.DAT
Severity:
4
Meaning:
The LLC2 LAN Card file has been updated.
Action:
None.
564.
IPX Filter Def File Upd:IPXFPAR.DAT
Severity:
4
Meaning:
The IPX Filter Definitions file has been updated.
Action:
None.
565.
IPX Filt App File Upd:IPXFLTAP.DAT
Severity:
4
Meaning:
The IPX Filter Applications file has been updated.
Action:
None.
701.
SDLC Rem. Link Stn Not Responding
Severity:
2
Meaning:
Self-explanatory. (
Action:
Check the PU to make sure it is operational.
702.
SDLC Link Stn Sent DM
Severity:
2
Meaning:
The link station sent a Disconnect Mode response, and the logical
link is down.
Action:
None.
704.
SDLC Link Stn rcvd FRMR, Inv. cmd
Severity:
2
Meaning:
The remote device received an invalid command and responded
with a Frame Reject.
Action:
None.
is the Remote Link Station.)