Cabletron Systems SmartSwitch 6000 User Manual page 243

Frame relay module for mmac-plus
Hide thumbs Also See for SmartSwitch 6000:
Table of Contents

Advertisement

Destination Subscriber
SVC Retry Timer
SVC Idle Timer
Max VCs to Establish
PVC Connection
IPXWAN Enabled
Source Card/Port/DLCI
Configuring IPX
is a subscriber ID associated with the physical X.25 port that will be used for the IPX
interface. (See the footnote following Table 12-9.)
is the frequency with which calls will be placed to try to establish a connection.
is a period that an IPX connection can remain active with no traffic before the con-
nection is cleared.
specifies a number of virtual circuits over which IPX traffic will be transmitted in par-
allel.
identifies this interface as one end of a PVC.
Table 12-10 IPX Frame Relay Interface Parameters
Parameter
IPXWAN Enabled
Source Card
Source Port
Source DLCI
Make sure the port is not configured (in the Port record) for backup use only. (See
1
Chapter 5.)
Make sure the DLCI is not part of a frame relay DLCI backup group or intra-nodal frame
2
relay PVC (both described in Chapter 7).
determines whether Novell's IPXWAN protocol will be used on the interface.
IPXWAN specifies a method for IPX routers to communicate across WAN links. FRX
and FRM implement IPXWAN running over RFC 1490-compliant frame relay and
RFC1356-compliant X.25.
identifies the location of this end of the frame relay IPX interface.
Make sure the physical frame relay port is not reserved for
backup DLCIs (as determined by the
parameter in the port record—see Chapter 6).
Also make sure the DLCI is not part of a frame relay DLCI
backup group or frame relay PVC.
Valid Values
Y/N
FRX4000, FRM:
0
FRX6000:
0–7
1
0–7
2
16–991
For Backup Use Only
Default Value
N
0
0
16
12-15

Advertisement

Table of Contents
loading

Table of Contents