Cabletron Systems SmartSwitch 6000 User Manual page 52

Frame relay module for mmac-plus
Hide thumbs Also See for SmartSwitch 6000:
Table of Contents

Advertisement

Node Name
Remote Control ID
Remote Control Pwd
File Transfer ID
File Transfer Pwd
Collecting Node ID
Collecting Node Pwd
Primary Alarm Output ID
3-6
is displayed at the upper right of the screen when the device is being controlled by the
"local" keyboard and monitor. (If the local operator is controlling a remote FRX/FRM,
the
of that device will be displayed as the local
Remote Control ID
is required if a remote FRX, FRM, or async terminal will be used to take control of the
local FRX/FRM (via a physical or logical port in the local device). The ID will be
checked against the called address fields of incoming Call Requests. The remote
device can be a terminal connected to an async PAD port on a remote FRX/FRM, or
the remote FRX/FRM itself.
Make sure that each FRX/FRM on the same network is assigned
a diferent
is a password used in conjunction with the
against the user data field of a Call Request packet. Both the
the password must match what is expected, or the FRX/FRM will not accept a request
for remote control.
is used for file transfers (see page 16-4) to or from this FRX/FRM. The ID will be
checked against the called address field of a Call Request packets coming into this
FRX/FRM.
is a password used in conjunction with the
and the
File Transfer Pwd
accept a request for file transfer.
is defined on a collecting node (described later) for use by other FRXs and/or FRMs
that send their alarms to that collecting node. This same ID must be configured on each
non-clooecting node as the
function on non-collecting nodes.
is a password that will be checked to verify that the
used for alarms. Since the same ID can be specified for several functions, the software
processes can use the passwords to identify the different functions.
Any non-alarm passwords must be different than any alarm
passwords. Unless you are certain you are not duplicating a
password, leave all passwords at the default settings.
specifies where alarms will be sent. For a device configured as a collecting node, the
ID is usually a printer port (async PAD port on FRX4000; serial, parallel, or async
PAD port on FRX6000 or FRM); for non-collecting nodes, the ID is usually the
.
Remote Control ID
Remote Control ID
File Transfer ID
must match what is expected, or the FRX/FRM will not
Primary Alarm Output ID
Node Name
, and will be checked
Remote Control ID
. Both the
File Transfer ID
. The
Collecting Node ID
Primary Alarm Output ID
FRX/FRM 3.3 User Guide, Rev 04
.)
and
has no
is being

Advertisement

Table of Contents
loading

Table of Contents