System Events
705.
SDLC Stn rcvd FRMR, IFLD invalid
Severity:
2
Meaning:
The remote device received an unpermitted I frame and responded
with a Frame Reject.
Action:
None.
706.
SDLC Stn rcvd FRMR, Nr invalid
Severity:
2
Meaning:
The remote device received a frame with an invalid N(r) and
responded with a Frame Reject.
Action:
None.
707.
SDLC Stn rcvd FRMR, Ifld too long
Severity:
2
Meaning:
The remote device received an I frame that was too long, and
responded with a Frame Reject.
Action:
None.
708.
SDLC Rem Stn sent Invalid Command
Severity:
2
Meaning:
The remote device received an invalid or unsupported command.
Action:
None.
709.
SDLC Rem Stn sent unexpected IFLD
Severity:
2
Meaning:
The remote device sent an unpermitted I frame.
Action:
None.
710.
SDLC Rem Stn sent invalid Nr
Severity:
2
Meaning:
The remote device sent a frame with an invalid N(r).
Action:
None.
711.
SDLC Rem Stn Exceeded window size
Severity:
2
Meaning:
The number of frames sent by the remote device has exceeded the
window size.
Action:
None.
712.
SDLC Station Inactivity timer exp
Severity: