Configuring Frame Relay Backup Groups; Frame Relay Backup Group Parameters - Cabletron Systems SmartSwitch 6000 User Manual

Frame relay module for mmac-plus
Hide thumbs Also See for SmartSwitch 6000:
Table of Contents

Advertisement

Configuring Frame Relay Backup Groups

RLP
Entry
Configuring Frame Relay
A Frame Relay Backup Group is one or more DLCIs (on the same RLP) that can act
as a backup for one or more "primary" DLCIs (also on the same RLP). If a node
detects a failure in a primary DLCI connection, the software will search any DLCI in
the backup group configured for the primary DLCI, and will select the first available
one as a backup. The backup will become operational and will remain in that state until
the primary becomes active again. If the backup fails while in use, the software will
check the status of the primary, then (if necessary) search the primary's backup group
for another backup.
Any sessions in progress when a primary DLCI goes down will not be
transferred directly to the backup DLCI, but will be reset, then established
on the backup.
To review existing backup groups, press
figuration Menu (or
[A], [F], [A]
To configure a backup group, press
ration Menu. When prompted, enter:
Frame Relay Backup Group Number
Any other requested information, noting Table 6-8.
Table 6-8 Frame Relay Backup Group Parameters
Parameter
RLP
Entr y
Por t
DLCI
WaitTimer
ProtEnab
Delete?
allows deleting an entry
1 Must be on the same RLP as the primary DLCI (the one being backed up).
2 The DLCI must have already been created in Port Configuration. Also, a DLCI cannot
be assigned to more than one backup group, nor can it be assigned to a backup group if
it is a primary DLCI (one that will be backed up).
3 See explanation.
identifies the RLP containing the primary and backup DLCIs.
is simply an identifier.
at the Frame Relay Backup Groups Con-
[A]
from the Main Menu).
at the Frame Relay Backup Groups Configu-
[B]
:
. (The default is
1–255
Valid Values
FRX4000, FRM:
0–7
FRX6000:
0–9
0–7
1
2
16–991
0–65535
(seconds)
Y/N
n/a
.)
1
Default Value
0
0
0
0
16
120
3
N
n/a
6-35

Advertisement

Table of Contents
loading

Table of Contents