Physical Port Interface
Blocked Port Flag
X.3 Line Speed
Initial Profile Name
Configuring Async Ports
must be configured as follows. For reference, port locations are shown on page 5-1
(FRX4000), page 5-2 (FRX6000), and page 5-3 (FRM).
FRX4000 port 0 is always
FRX4000 port 1 is
DSU card is installed.
FRX4000 ports 2 and 3 are determined by the attached cables: RS-232, V.35,
RS-449, or X.21.
FRX4000 ports 4–7 are determined by the expansion Line Interface Card (LIC)
and attached I/O cables. Line Processor Configuration identifies the LIC, and
only the valid interfaces will be displayed on the Port screen. Possible interfaces
are RS-232, V.35, RS-449, and X.21. (RS-449 and X.21 interfaces require an
RS-422 LIC, which is available by special order.)
FRX6000 ports 0–7 on each RLP are determined by the Line Interface Card(s)
and attached I/O cables. Line Processor Configuration identifies the LIC, and
only the valid interfaces will be displayed on the Port screen. Possible interfaces
are RS-232, V.35, RS-449, and X.21
require an RS-422 LIC.)
FRM ports 0–7 are determined by the Line Interface Cards and attached I/O
cables. Line Processor Configuration identifies the LICs, and only the valid
interfaces will be displayed on the Port screen
V.35, RS-449, and X.21
LIC. Also, RS-530 and X.21 are available through special order only.)
will cause the port to be enabled (
in that state until this parameter is changed or an on-line enable (
Main Menu) or disable (
is the data transmission rate in bits per second. Specify the line speed that matches (as
closely as possible) the configuration of the device connected to the port.
Selecting this item displays a list of valid line speeds. To specify a speed, press the
letter corresponding to the speeds. Valid speeds are:
50
75
134.5
150
1200
1800
19.2K
38.4K
Selecting
Autobaud
mission from the async device, then set automatically.
is an async PAD profile (described on page 10-2) that will be in effect on this port until
the user of the async device logs into the PAD, at which time the profile in the PAD
Logins record (described on page 10-7) becomes effective. (If
record for
Login Required
ified profile is not defined in the database, the default profile,
.
RS-232
or
, depending on whether the optional CSU/
RS-232
DSU
. (RS-449, RS-530, and X.21 i
. (RS-449, RS-530, and X.21 i
) or disabled (
N
from the Main Menu) is performed.
[B], [B], [A]
75/1200
200
2400
57.6K
causes the line speed to be read from the first trans-
, the profile in the Port record is always in effect.) If the spec-
nterfaces
Possible interfaces are RS-232,
.
nterfaces require an RS-422
) at node IPL. The port will remain
Y
[B], [B], [C]
100
300
4800
Autobaud
is selected in the Port
N
, will be in effect.
90
from the
110
600
9600
10-11