Function
Name
code
control
threshold
of motor 2
0:No operation
Energy-sa
1:Automatic energy-saving operation (reserved)
P04.26
ving
Motors will automatically adjust the output voltage to
operation
save energy when light loads.
Select the output setting channel at V/F curve
separation.
0: Keypad: the output voltage is determined by
P04.28.
1:AI1 ;
2:AI2;
3:AI3;
Voltage
4:HDI;
P04.27
setting
5:Multi-step speed;
6:PID;
7:MODBUS communication;
8:PROFIBUS/CANopen communication;
9:Ethernet communication;
10: Reserved
Note: 100% corresponds to the rated voltage of the
motor.
Keypad
The function code is the voltage displaying when the
P04.28
setting
voltage is set through keypad.
voltage
The setting range:0.0%~100.0%
Voltage
Voltage increasing time is the time when the inverter
P04.29
increasing
accelerates from the output minimum voltage to the
time
output maximum voltage.
Voltage decreasing time is the time when the inverter
Voltage
decelerates from the output maximum voltage to the
P04.30
decreasing
output minimum voltage.
time
The setting range:0.0~3600.0s
P04.31
Maximum Set the upper and low limit of the output voltage.
Detailed instruction of parameters
86
www.barghmaher.ir
Function codes
Default
Modify
value
Hz
◎
0
○
0
100.0
○
%
○
5.0s
○
5.0s
◎
100.0