INVT Goodrive 35 Series Operation Manual page 209

Close loop vector control inverter
Hide thumbs Also See for Goodrive 35 Series:
Table of Contents

Advertisement

inverters
Goodrive35
0
1
2
3
.
.
.
.
.
P06.00
HDO output type selection
.
0
19
1
20
0: open collector high speed pulse
P06.00
output
1: open collector output
Output instructions:
Set value
0
Running frequency
1
Set frequency
2
Ramp given frequency
3
Running speed
Output current
4
(relative to the inverter)
Output current (relative to the
5
6
Output voltage
7
Output power
8
Setting torque value
9
Output torque
10
11
12
13
14
Setting value 1 of MODBUS -1000~1000,1000 corresponds to 100.0%
Analog output selection
P06.17
P06.14
P06.18
P06.19
P06.20
(default value is 0)
P06.22
P06.23
P06.15
P06.24
P06.25
(default value is 0)
P06.27
P06.28
P06.16
P06.29
P06.30
(default value is 0)
P06.01 P06.02 P06.03 P06.04 output selection
0
Running frequency
3
Running rotation speed
6
Output voltage
9
Output torque
12
Analog AI3 input value
15
MODBUS communication setting 2
Torque current (relative to the nominal
18
current of the motor)
Function
0~ the Max. output frequency
0~ the Max. output frequency
0~ the Max. output frequency
0~2 times of the rated synchronous rotation speed of
the motor
0~2 times of the rated current of the inverter
0~2 times of the rated current of the inverter
motor)
0~1.5 times of the rated voltage of the inverter
0~2 times of the rated power
0~2 times of the rated current of the motor
0~2 times of the rated current of the motor
AI1
0~10V/0~20mA
AI2
0~10V/0~20mA
AI3
-10V~10V
HDI
0.00~50.00kHz
www.barghmaher.ir
Basic operation instruction
Analog output curve setting
Analog output filter setting
P06.21
P06.26
P06.31
1
Set frequency
4
Output current (relative to the inverter)
7
Output power
10
Analog AI1 input value
13
HDI input value
16
PROFIBUS communication setting 1
Exciting current (relative to the nominal
19
current of the motor)
Instructions
208
AO1
AO2
HDO
2
Ramp given frequency
5
Output current (relative to the motor)
8
Set torque
11
Analog AI2 input value
14
MODBUS communication setting 1
17
PROFIBUS communication setting 1
20
Reserved

Hide quick links: