inverters
Goodrive35
Function
Name
code
detection
This parameter is used to see the speed deviation
detection time
Speed
deviation
P11.15
detection
time
Setting range: 0.0~10.0s
Open loop
0:Invalid
vector and
P11.16
1:Valid; ensure rated output torque when voltage
VF 0Hz
drop
output
P12 Group
Motor 2
0:Asynchronous motor
Motor type
1:Synchronous motor
P12.00
2
Note: switch the current motor by the switching
channel of P08.31.
Rated
power of
P12.01
asynchron
0.1~3000.0kW
ous motor
2
Rated
frequency
of
0.01Hz~P00.03(the Max.
P12.02
asynchron
frequency)
ous motor
2
P12.03
Rated
1~36000rpm
Detailed instruction of parameters
Set the parameter of
the controlled
asynchronous motor.
In order to ensure the
controlling
performance, set the
P12.01~P12.05
according to the name
plate of the
asynchronous motor.
Goodrive35 series
inverters provide the
135
www.barghmaher.ir
Function codes
Default
Modify
value
○
1.0s
○
0
◎
0
Depend
◎
on
model
50.00
◎
Hz
◎
Depend
Need help?
Do you have a question about the Goodrive 35 Series and is the answer not in the manual?