When the function code is set as 0.0, the
communic
communication overtime parameter is invalid
ation
When the function code is set as non-zero, if the
overtime
interval time between two communications exceeds
the communication overtime, the system will report
"485 communication faults" (CE).
Generally, set it as invalid; set the parameter in the
continuous communication to monitor the
communication state.
0:Alarm and stop freely
1:No alarm and continue to run
Transmissi
2:No alarm and stop according to the stop mode
P14.05
on fault
(only under the communication control)
processing
3:No alarm and stop according to the stop mode
(under all control modes)
0x00~0x11
LED ones:
0: Write with response: the inverter will respond to all
reading and writing commands of the upper monitor.
1: Write without response: the inverter only responds
Communic
to the reading command other than the writing
P14.06
ation
command of the drive. The communication efficiency
processing
can be increased by this method.
LED tens:
0: Communication encrypting valid
1: Communication encrypting invalid
P15 Group PROFIBUS/CANopen function
0: PROFIBUS;
Module
P15.00
1: CANopen
type
Select communication protocol
Detailed instruction of parameters
145
www.barghmaher.ir
Function codes
Default
Modify
value
0
0x00
0