Goodrive35 inverters
Environment
Humidity
Storage
temperature
Running
environment
condition
Altitude
Vibration
Installation direction
Note:
Goodrive35 series inverters should be installed in a clean and ventilated environment
according to enclosure classification.
Cooling air must be clean, free from corrosive materials and electrically conductive dust.
4.2.2 Installation direction
The inverter may be installed on the wall or in a cabinet.
The inverter must be installed in an upright position. Check the installation site according to the
requirements below. Refer to chapter Dimension Drawings in the appendix for frame details.
run after a long stop, it is necessary to provide an external heating
device to increase the internal temperature, otherwise damage to
the devices may occur.
RH≤90%
No condensation is allowed.
The maximum relative humility should be equal to or less than
60% in corrosive air.
-30~+60℃
The installation site of the inverter should:
keep away from the electromagnetic radiation source;
keep away from contaminative air, such as corrosive gas, oil mist
and flammable gas;
ensure foreign objects, such as metal power, dust, oil, water can
not enter into the inverter(do not install the inverter on the
flammable materials such as wood);
keep away from direct sunlight, oil mist, steam and vibration
environment.
<1000m
If the sea level is above 1000m, please derate 1% for every
additional 100m.
≤ 5.88m/s
2
(0.6g)
The inverter should be installed on an upright position to ensure
sufficient cooling effect.
24
www.barghmaher.ir
Installation guidelines
Conditions
Need help?
Do you have a question about the Goodrive 35 Series and is the answer not in the manual?
Questions and answers