INVT Goodrive 35 Series Operation Manual page 302

Close loop vector control inverter
Hide thumbs Also See for Goodrive 35 Series:
Table of Contents

Advertisement

inverters
Goodrive35
Bit
PZD2
0: Invalid
sending
1: Running frequency(*100, Hz)
2: Set frequency(*100, Hz)
PZD3
3: Bus voltage(*10, V)
sending
4: Output voltage(*1, V)
PZD4
5: Output current (*10, A)
sending
6:
PZD5
value(*10, %)
sending
7:
Output
PZD6
(*10, %)
sending
8: Running rotating speed(*1, RPM)
PZD7
9: Running linear speed (*1, m/s)
sending
10: Ramp given frequency
PZD8
11: Fault code
sending
12: AI1 value (*100, V)
PZD9
13: AI2 value (*100, V)
sending
14: AI3 value (*100, V)
PZD10
15: PULSE frequency value (*100,
sending
kHz)
PZD11
16: Terminals input state
sending
17: Terminals output state
18: PID given (*100, %)
PZD12
19: PID feedback (*100, %)
sending
20: Motor rated torque
PKW area (parameter identification marks PKW1-value area). PKW area describes
treatment of parameter identification interface, PKW interface is a mechanism which
determine parameters transmission between two communication partners, such as reading
and writing parameter values.
Name
Output
torque
power
actual
301
www.barghmaher.ir
Function selection
actual
value
Appendix A
0
0
0
0
0
0
0
0
0
0
0

Hide quick links: