0
1
P05.00
(HDI input type selection )
0: HDI is high speed pulse input
P05.00
1: HDI is switch input
Relative parameters list:
Function
code
P05.00
HDI input selection
P05.32
Lower limit of AI1
Corresponding setting of
P05.33
the lower limit of AI1
P05.34
Upper limit of AI1
Corresponding setting of
P05.35
the upper limit of AI1
P05.36
AI1 input filter time
P05.37
Lower limit of AI2
Corresponding setting of
P05.38
the lower limit of AI2
P05.39
Upper limit of AI2
Corresponding setting of
P05.40
the upper limit of AI2
P05.41
AI2 input filter time
Lower limit of
P05.42
Corresponding setting of
P05.43
the lower limit of AI3
AI1 input voltage
P17.19
AI1
AI2 input voltage
P17.20
AI2
AI3 input voltage
P17.21
AI3
HDI input frequency
P17.22
0
HDI
1
2
P05.49
(HDI high speed pulse input function selection )
0: frequency setting input
P05.49
1: counter input
2: length counter input
Name
Detailed instruction of parameters
0: High pulse input
1: Digital input.
0.00V~P05.25
-300.0%~300.0%
P05.23~10.00V
-300.0%~300.0%
0.000s~10.000s
0.00V~P05.30
-300.0%~300.0%
P05.28~10.00V
-300.0%~300.0%
0.000s~10.000s
-10.00V~P05.35
AI3
-300.0%~300.0%
206
www.barghmaher.ir
Basic operation instruction
Analog curve input setting
P05.32
P05.33
P05.34
P05.35
P05.37
P05.38
P05.39
P05.40
P05.42
P05.43
P05.44
P05.45
P05.46
AI3
P05.47
AI1/AI2/HDI
P05.50
P05.51
P05.52
P05.53
Analog input filter
P05.36
P05.41
P05.48
P05.54
Default
value
0
0.00V
0.0%
10.00V
100.0%
0.030s
0.00V
0.0%
10.00V
100.0%
0.030s
-10.00V
-100.0%
Need help?