Function
Name
code
Simple
Below is the detailed instruction:
PLC 0~7
P10.34
step
ACC/DEC
time
Simple
PLC 8~15
P10.35
step
ACC/DEC
time
After users select the corresponding ACC/DEC time,
the combining 16 binary bit can be changed into
hexadecimal bit, and then set the corresponding
function codes.
ACC/DEC time 1 is set by P00.11 and P00.12;
ACC/DEC time 2 is set by P08.00 and P08.01;
ACC/DEC time 3 is set by P08.02 and P08.03;
ACC/DEC time 4 is set by P08.04 and P08.05.
Setting range: 0x0000~0xFFFF
0: Restart from the first step; stop during running
PLC
(cause by the stop command, fault or power loss),
P10.36
restart
run from the first stage after restart.
1: Continue to run from the stop frequency; stop
Detailed instruction of parameters
Function
Binary bit
Step
code
BIT1
BIT0
0
BIT3
BIT2
1
BIT5
BIT4
2
BIT7
BIT6
3
P10.34
BIT9
BIT8
4
BIT11
BIT10
5
BIT13
BIT12
6
BIT15
BIT14
7
BIT1
BIT0
8
BIT3
BIT2
9
BIT5
BIT4
10
BIT7
BIT6
11
P10.35
BIT9
BIT8
12
BIT11
BIT10
13
BIT13
BIT12
14
BIT15
BIT14
15
130
www.barghmaher.ir
ACC/
ACC/
ACC/
ACC/
DEC 0
DEC 1
DEC 2
DEC 3
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
00
01
10
11
Function codes
Default
Modify
value
0x000
○
0
0x000
○
0
◎
0
Need help?
Do you have a question about the Goodrive 35 Series and is the answer not in the manual?
Questions and answers