INVT Goodrive 35 Series Operation Manual page 304

Close loop vector control inverter
Hide thumbs Also See for Goodrive 35 Series:
Table of Contents

Advertisement

inverters
Goodrive35
Request label (From master to slave)
Modification parameter value (double word)
3
[only change RAM]
Modification parameter value (one word)
4
[RAM and EEPROM are modified]
Modification parameter value (double word)
5
[RAM and EEPROM are modified]
Request label
"2"-modification parameter value (one word) [only change RAM],
"3"-modification parameter value (double word) [only change RAM]
"5"-modification parameter value (double word) [RAM and EPROM are modified] not support
currently.
Reponses logo PKW1 defines as below:
Confirmation
0
No response
1
Transmission parameter value ( one word)
2
Transmission parameter value ( two words)
Task can not be executed and returns the following error number:
0: Illegal parameter number
1: Parameter values can not be changed (read-only parameter)
2: Out of set value range
3: The sub-index number is not correct
4: Setting is not allowed (only reset)
5: Data type is invalid
3
6: The task could not be implemented due to operational state
7: Request isn't supported.
8: Request can't be completed due to communication error
9: Fault occurs when write operation to stationary store
10: Request fails due to timeout
11: Parameter can not be assigned to PZD
12: Control word bit can't be allocated
13: Other errors
Response label (From slave to master)
303
www.barghmaher.ir
Response label
2
1
2
Function
Appendix A
3 or 4
3 or 4
3 or 4