inverters
Goodrive35
Function
Name
code
The setting range:0.00Hz~P00.03
(the Max. frequency)
This parameter is used to control the internal braking
Energy
pipe inside the inverter.
P08.37
braking
0:Disable
enable
1:Enable
Note: Only applied to internal braking pipe.
After setting the original bus voltage to brake the
energy, adjust the voltage appropriately to brake
P08.38
the load. The factory changes with the voltage
level.
Threshold
The setting range:200.0~2000.0V
voltage
In order to prevent customers set the value is too
large, it is recommended setting range:
Cooling
0: Normal mode
P08.39
fan running
1:The fan keeps running after power on
mode
0x000~0x111
LED ones: PWM mode selection
PWM
P08.40
0: PWM mode 1, three-phase modulation and
selection
two-modulation
1: PWM mode 2, three-phase modulation
Detailed instruction of parameters
voltage
380V
range
685~750V
117
www.barghmaher.ir
Function codes
Default
value
1
380V
voltage:
700.0V
660V
voltage:
1120.0V
660
1080~1180V
0
0x001
Modify
○
○
○
◎
Need help?
Do you have a question about the Goodrive 35 Series and is the answer not in the manual?
Questions and answers