Function
Name
code
current
Original
0: No test
P13.01
pole test
1: High-frequency superposition (reserved)
mode
2: Pulse superposition
Source current is the positioning current of the
magnetic pole position. Source current 1 is valid
Source
under the frequency point of current shifting.
P13.02
current 1
Increasing the value can raise the starting torque.
Setting range: 0.0%~100.0% (rated current of the
motor)
Source current is directional current of the magnetic
pole position. Source current 2 is valid under the
Source
frequency point of current shifting. There is no need
P13.03
current 2
to modify the value generally.
Setting range: 0.0%~100.0%(rated current of the
motor)
Shift
frequency
P13.04
0.0%~80.0% (the Max. frequency)
of source
current
Superposi
ng
P13.05
200~1000Hz
frequency
(reserved)
Pulse
P13.06
superposin
0.0~300.0%(rated voltage of the motor)
g voltage
P13.07
Reserved 0~65535
Control
P13.08
parameter
0x0000~0xFFFF
1
Control
P13.09
parameter
0.00~655.35
2
Detailed instruction of parameters
142
www.barghmaher.ir
Function codes
Default
Modify
value
0
20.0%
10.0%
20.0%
500Hz
50.0%
0
0x000
0
2.00