Procedure
1. Select the menu entry [Tools → Import Fieldbus Device...].
2. Select the XDD file (for example, 0x0300008D_ISD510_S.xdd or 0x0300008D_ISD510_A.xdd) from its location on the hard drive. This
import only needs to be done once per project. The device is then known to Automation Studio™.
3. Now add the SDM 511/SDM 512 drive module or servo drive to the Ethernet POWERLINK
View:
Right-click on the controller in the Physical View and select [Open POWERLINK].
Right-click on the interface and select Insert...
In the Select controller module window, select the servo drive in the group POWERLINK Devices.
Click on Next.
In the next window, enter the node number of the servo drive.
Illustration 64:
92 | Danfoss A/S © 2019.10
Adding a Servo Drive to the Project in V3.0.90