24/48 V Cable Cross Sections For Psm; Lcp Connector (M8, 6-Pole) - Danfoss VLT MSD 510 Operating Manual

Multiaxis servo drive
Table of Contents

Advertisement

Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
Illustration 137:
U
Connector
AUX
Table 137: Pin Assignment of U
Pins
De‐
Notes
scrip‐
(left to
tion
right)
1
24 V
Used for 24–48 V DC in-
AUX
put to the Power Supply
Module (PSM 510).
2
GND
Only PELV potential can be connected to the U
-

11.7.5.1 24/48 V Cable Cross Sections for PSM 510

Table 138: 24/48 V Cable Cross Sections for PSM 510
Minimum cable cross section for CE (minimum 70 °C, Cu)
Minimum cable cross section for UL (minimum 60 °C, Cu)

11.7.6 LCP Connector (M8, 6-pole)

The LCP connector is located on the front of all the system modules. It used to connect the LCP directly via a cable.
222 | Danfoss A/S © 2019.10
Connector
AUX
Rating/parameter
Nominal input voltage: 24 V/48 V DC ±10%
Nominal current: Depends on the number of servo drives in the application.
Maximum current: 50 A
Maximum cross-section: 16 mm
Maximum cable length: 3 m
Conductor cross-section range 0.75–16 mm
AUX
N O T I C E
input.
2
2
, solid or flexible (AWG 18–AWG 4)
AQ262450196490en-000101 / 175R1170
Specifications
2
16 mm
4 AWG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT MSD 510 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents