Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
Table 24: Operating LEDs on SDM 511 and SDM 512
LED
DEV
SVS ST
NET ST
LINK/ACT X1
(Link/activity status of In)
LINK/ACT X2
(Link/activity status of Out)

7.2.2 Operating LEDs on the PSM 510

STATUS PSM
DEV
SVS ST
NET ST
LINK/ACT
X1
X2
Illustration 110:
Operating LEDs on PSM 510
Danfoss A/S © 2019.10
Color
Flash status
Green
On
Flashing
Red
On
Flashing
Green
On
Off
Green/red
Fieldbus depend-
ent
Green
On
Flashing
Off
Green
On
Flashing
Off
Description
Device is in state Operation enabled.
Auxiliary voltage is applied.
Device is in state Fault or Fault reaction active.
DC-link is not applied.
24 V safety supply is applied.
24 V safety supply is not applied.
Network status of the device (see corresponding fieldbus stand-
ard).
Ethernet link established.
Ethernet link established and active.
No link.
Ethernet link established.
Ethernet link established and active.
No link.