Illustration 102:
Logical View of Indirect Ethernet-based Fieldbus Communication (Communication via PLC)
The logical view only shows the connectivity from a high-level software perspective and does not reflect the actual physical
-
topology of the network.
6.16.4.3.2 Network Settings for Indirect Communication
Any network interface can be used to communicate through a PLC. A dedicated network interface is not required.
When establishing the communication through a PLC, the VLT
Address Translation (NAT). Adding a route to the Windows routing table requires administrator privileges. Therefore, administrator
credentials may be requested when initializing the connection.
6.16.4.3.3 Enabling Indirect Communication
Context:
Carry out the following steps to enable indirect communication.
When observing the network packets via Wireshark
transmitted are handed over to Wireshark
checksums as invalid, even though the packets contain valid checksums when they leave the network hardware later. Use 1 of
these 2 methods to avoid this checksum offloading problem:
Turn off the checksum offloading in the network driver if possible.
-
-
Turn off the checksum validation of the specific protocol in the Wireshark
Disable IPv6 on the network interfaces used for communication on the PC:
136 | Danfoss A/S © 2019.10
. . .
2
n
A
PLC
B
®
, checksum offloading often causes confusion as the network packets to be
®
before the checksums have been calculated. Wireshark
N O T I C E
®
Servo Toolbox configures a routing table using the selected Network
N O T I C E
®
preferences.
Commissioning
®
shows these empty
AQ262450196490en-000101 / 175R1170
Need help?
Do you have a question about the VLT MSD 510 and is the answer not in the manual?