Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
Table 25: Operating LEDs on PSM 510
LED
DEV
SVS ST
NET ST
LINK/ACT X1
(Link/activity status of In)
LINK/ACT X2
(Link/activity status of Out)
7.2.3 Operating LEDs on the DAM 510
STATUS DAM
DEV
SVS ST
NET ST
AUX
LINK/ACT
X1
X2
X3
Illustration 111:
Operating LEDs on DAM 510
150 | Danfoss A/S © 2019.10
Color
Flash status
Green
On
Flashing
Red
On
Flashing
Green
On
Off
Green
On
Orange
On
Red
Flashing
On
Green
On
Flashing
Off
Green
On
Flashing
Off
Description
Device is in state Operation enabled.
Device is in state Standby or Power-up.
Device is in state Fault or Fault reaction active.
Input mains is not applied.
24 V safety supply is applied.
24 V safety supply is not applied.
Connected.
Online.
Initialization.
Initialization failed or other error.
Ethernet link established.
Ethernet link established and active.
No link.
Ethernet link established.
Ethernet link established and active.
No link.
AQ262450196490en-000101 / 175R1170
Operation
Need help?
Do you have a question about the VLT MSD 510 and is the answer not in the manual?
Questions and answers