Danfoss VLT MSD 510 Operating Manual page 231

Multiaxis servo drive
Table of Contents

Advertisement

Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
Table 149: Pin Assignment of STO Connectors on the Top of DAM 510
Connec‐
Pins
De‐
tor
scrip‐
name
tion
STO DAM
1
STO–
2
STO+
3
STO–
4
STO+
Only PELV potential can be connected to the STO inputs.
-
11.7.10.3.2 STO Connector on the Bottom of DAM 510
There is 1 output STO connector on the bottom of the Decentral Access Module (DAM 510). The output is for the hybrid cable.
Illustration 149:
STO Connector on the Bottom of DAM 510
Table 150: Pin Assignment of STO Connector on the Bottom of DAM 510
Connec‐
Pins
De‐
tor
scrip‐
name
(left to
tion
right)
STO DAM
1
STO+
2
STO–
Danfoss A/S © 2019.10
Notes
Rating/parameter
Used for STO output
Nominal voltage: 24 V DC ±10%
voltage to the input
of the other system
Nominal current: Depends on the number of servo drives in the applica-
modules.
tion.
Used for STO input
Maximum current: 1 A
voltage.
Conductor cross-section range: 0.2–1.5 mm
N O T I C E
Notes
Used for the STO
output from the
DAM to the hybrid
cable.
Rating/parameter
Nominal voltage: 24 V DC ±10%
Nominal current: Depends on the number of servo drives in the appli-
cation.
Maximum current: 1 A
Conductor cross-section range: 0.2–1.5 mm
Plug terminal tightening torque: 0.22–0.25 Nm
Specifications
2
(AWG 24–AWG 16)
2
(AWG 24–AWG 16)
AQ262450196490en-000101 / 175R1170| 231