Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
Table 26: Operating LEDs on DAM 510
LED
DEV
SVS ST
NET ST
AUX
(State of the auxiliary voltage)
LINK/ACT X1
(Link/activity of In)
LINK/ACT X2
(Link/activity status of Hybrid Out)
LINK/ACT X3
(Link/activity status of Out)
Danfoss A/S © 2019.10
Color
Flash status
Green
On
Flashing
Red
On
Flashing
Green
On
Off
Green
On
Orange
On
Red
Flashing
On
Green
On
Off
Red
On
Green
On
Flashing
Off
Green
On
Flashing
Off
Green
On
Flashing
Off
Description
Device is in state Operation enabled.
Device is in state Standby or Power-up.
Device is in state Fault or Fault reaction active.
DC-link is not applied at the input.
24 V safety supply is applied.
24 V safety supply is not applied.
Connected.
Online.
Initialization.
Initialization failed or other error.
Auxiliary voltage is applied to the output connector.
Auxiliary voltage is not applied to the output connector.
Auxiliary voltage undervoltage detected in the hardware.
Ethernet link established.
Ethernet link established and active.
No link.
Ethernet link established.
Ethernet link established and active.
No link.
Ethernet link established.
Ethernet link established and active.
No link.
AQ262450196490en-000101 / 175R1170| 151
Operation
Need help?
Do you have a question about the VLT MSD 510 and is the answer not in the manual?
Questions and answers