Sto Connectors On Psm 510 - Danfoss VLT MSD 510 Operating Manual

Multiaxis servo drive
Table of Contents

Advertisement

Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
1
2
Illustration 144:
STO Connectors on SDM 511/SDM 512
Table 147: Pin Assignment of STO Connectors on SDM 511/SDM 512
Connector name
Pins
SDM511:
1
STO SDM
2
SDM512:
3
STO SDM1
STO SDM2
4
Only PELV potential can be connected to the STO inputs.
-

11.7.10.2 STO Connectors on PSM 510

There is 1 input and 1 output STO connector on the Power Supply Module (PSM 510).
228 | Danfoss A/S © 2019.10
De‐
Notes
scrip‐
tion
STO–
Used for STO output
voltage 1/2 to the input
STO+
of the PSM 510,
DAM 510, or SDM 511/2.
STO–
Used for STO input volt-
age 1/2.
STO+
Rating/parameter
Nominal voltage: 24 V DC ±10%
Nominal current: Depends on the number of servo drives in
the application.
Maximum current: 1 A
Conductor cross-section range: 0.2–1.5 mm
AWG 16)
N O T I C E
Specifications
2
(AWG 24–
AQ262450196490en-000101 / 175R1170