Siemens HiPath 3000 Series Service Documentation page 805

Table of Contents

Advertisement

Nur für den internen Gebrauch
Step
9.
Fix the connection cable into place using cable binders.
10.
Replace the battery retainer and secure the mounting screw.
11.
Push the plug-in battery module into the left housing compartment up to the limit
stop.
12.
Screw on the front panel of the PB3000: To do so, tighten the four screws.
13.
Connect all of the power and connection cables of the PB3000.
14.
Insert the battery fuse on the rear of the PB3000 housing (see Section 9.1.3.1).
15.
Turn the switch for the line voltage in the front panel of the PB3000 and the switch
for the battery voltage on the back side of the PB3000 housing to the "On" position
(see Section 9.1.3.1).
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Expanding and Upgrading HiPath 3000