Service and Maintenance Tasks
Procedure: Exchanging boards
Step
1.
Disconnect system from power supply.
2.
Remove the board(s).
3.
Restart the system by plugging in the power plug.
4.
Delete board slot using user interface (29-4).
5.
Disconnect system from power supply.
6.
Insert new board(s).
7.
Restart the system by plugging in the power plug.
8.
Load customer data from the system.
Adapt customer data to new hardware configuration. Insert new board(s), (sta-
tions, for example).
9.
Load new customer data into the system.
12.3.2.2

Exchanging Workpoint Clients

You can add or remove workpoint clients while the system is in operation. The data in the re-
moved workpoint clients is retained.
In case of different telephone models, meaning ones that have a different number of program-
mable keys, the keypad layout of the previous model is retained. Add-on devices that are not
plugged in retain their technical features. With the HiPath 3000/5000 Manager E, you can de-
lete the add-on devices that are not plugged in and remove the keys that are no longer avail-
able.