power_calc.fm
Identifying System Power Requirements

HiPath 3800 Board Power Requirement

D.1
HiPath 3800 Board Power Requirement
Table D-1
Nominal Output of the HiPath 3800 Power Supply Unit
Power Supply Unit
LUNA2
Powerbox PB3000 with
LUNA2
1
The total max. nominal output at the 5-Vand at the –48-V output is 140 W. The 5-V nominal output can vary between 30
and 60 W and the -48-V nominal output can vary between 80 and 110 W. In other words, if 30 W are withdrawn at the 5-
V output, a maximum of 110 W is available at the -48-V output.
You must check whether the total power requirement of the boards used and the
>
connected workpoint clients of a system cabinet exceeds the maximum possible
LUNA2 output. Section D.7 contains a sample calculation.
Table D-2
HiPath 3800 Board Power Requirement
Board or Component
CBSAP
D
BSAP
DIU2U
DIUN2
DIUT2
IVMN8
IVMNL
REALS
RGMOD
S
LCN
SLMA
SLMA2
SLMA8
SLMO2
D-2
Part Number
S30122-K7686-A1
S30122-K7686-M1
S30177-U773-X with
S30122-K7686-M1
Part Number
S30810-Q2314-X
S30807-Q6722-X
S30810-Q2216-X
S30810-Q2196-X
S30810-Q2226-X100
S30122-H7688-X100
S30122-H7688-X
S30807-Q6629-X
S30124-X5109-X
S30810-Q2193-X300
S30810-Q2191-C300
S30810-Q2246-X
S30810-Q2191-C100
S30810-Q2168-X10
Nur für den internen Gebrauch
Max. Nominal Output in W
5 V
Net Power Requirement in
5 V
10.0
1.5
5.1
5.0
3.5
10.0
10.0
1.5
5.0
1.6
2.1
0.6
1.0
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
–48 V
1
140
110
W
–48 V
14.4
12.0
13.3
4.0
1.2