Siemens HiPath 3000 Series Service Documentation page 1044

Table of Contents

Advertisement

service.fm
Service
Guided Maintenance
Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
12-025 watchdog timer
interrupt
12-026 Data TLB inter-
rupt
12-027 Instruction TLB in-
terrupt
12-028 debug interrupt
Error Class 15 – Messages Concerning APS Transfer and Saving on Flash
15-000 !Req to switch
over APSXF
15-001 !APS switched
over KDS ok
15-002 !APS switched
over def. KDS
15-003 !CRC checksum
error
12-70
Meaning
HiPath 3800, Off-
set 0x1020,
Watchdog Timer
Interrupt
HiPath 3800, Off-
set 0x1100, Data
TLB Interrupt
HiPath 3800, Off-
set 0x1200, In-
struction TLB Inter-
rupt
HiPath 3800, Off-
set 0x2000, Debug
Interrupt
Request for APS
transfer.
APS transfer was
successful.
APS transfer was
not successful.
Default CDB load-
ed.
Error in CRC
checksum.
Required Measures
Create a trace.
Create a stack dump.
Save a snapshot.
Create a trace.
Create a stack dump.
Save a snapshot.
Create a trace.
Create a stack dump.
Save a snapshot.
Create a trace.
Create a stack dump.
Save a snapshot.
None
None
Check CDB version.
Check APS version.
Transfer APS again.
If the error persists, re-
place the MMC module.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Note