Siemens HiPath 3000 Series Service Documentation page 1065

Table of Contents

Advertisement

Nur für den internen Gebrauch
Table 12-8
Event Viewer Entries for the HiPath 5000 Server
Event
De-
Error
fault
trap
1023
X
Socket
not con-
nected
1024
CDB
transfer
success-
ful (read)
1025
CDB
transfer
success-
ful (write)
1027
CallAd-
dressTab
le and
NodeIpT-
able
transfer
success-
ful
1028
X
Venus
data-
base
closed
1029
X
Venus
Data-
base
started
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Meaning
text
Connection dif-
ficulties - HiPath
3000/5000
server. TCP
connection not
available
All frame pages
successfully
read from Hi-
Path 3000/5000
nodes by the
server
All frame pages
successfully
written from the
server to all Hi-
Path 3000/5000
nodes
Successful
transfer of call
address table
and node IP ta-
ble to the sys-
tem by the serv-
er
Venus data-
base closed
Venus data-
base started
User reaction
Save event
Check LAN, ini-
file for er-
tiate HiPath 3000/
ror analy-
5000 ping.
sis
Restart server if
necessary. Check
HiPath 3000/5000
HIP.
Information
Information
Information
Information
Information
service.fm
Service
Guided Maintenance
Cate-
Source
gory
fct
HiPath
AllServ
e
vsrv HiPath
AllServ
e
vsrv HiPath
AllServ
e
car
HiPath
AllServ
e
vsrv HiPath
AllServ
e
vsrv HiPath
AllServ
e
12-91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents