Using Snmp - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

h3h5_in_the_lan.fm
HiPath 3000/5000 in the LAN Network
Administration & Fault Management
13.10.2.3

Using SNMP

An MIB browser (available with Hewlett-Packard's "Network Node Managers") is required for
using SNMP functionality.
SNMP traps
Table 13-6
Generic SNMP Traps (MIB-2)
Trap
COLD START
WARM START
INTERFACE UP
INTERFACE DOWN
AUTHENTICATION ERROR (incorrect SNMP community name)
The following HG 1500-specific trap classes are available:
General traps
Reboot traps
Threshold/statistic, resource/diagnostic traps,
Security traps
License traps
Traps for internal errors
The following tables list the individual traps for each of these classes. A distinction is made un-
der "Type" between hardware traps (HW) and software traps (SW).
Table 13-7
General Traps (HG 1500-Specific)
Type
Trap Message
(SW/HW)
SW
MSG_GW_SUCCESSFULLY_STARTE
D
Table 13-8
Reboot Traps (HG 1500-Specific)
Type
Trap Message
(SW/HW)
SW
MSG_CAT_H323_REBOOT
SW
MSG_CAT_HSA_REBOOT
13-68
Nur für den internen Gebrauch
Description
Gateway successfully started
Description
Reboot with H.323
Reboot with HSA