power_calc.fm
Identifying System Power Requirements

HiPath 3300 Board Power Requirement

D.5
HiPath 3300 Board Power Requirement
Table D-9
Nominal Output of the HiPath 3300 Power Supply Units
Power Supply Unit
UPSC-DR
Powerbox PB3000 with
LUNA2
1
Nominal output = 40 W. Due to build-up of heat, not more than 20 W may be withdrawn.
You must check whether the total power requirement of the boards used and the
>
workpoint clients connected exceeds the maximum possible output of the UPSC-DR
with or without Powerbox PB3000. A sample calculation is shown in Section D.7.
Table D-10
Board Power RequirementHiPath 3300
Board or Component
BS3/1
BS3/3
CBRC
(including subboards) S30810-Q2935-Z301
HXGR3
IVMP8R
Fan for HiPath 3300
P
DM1
SLAD8R
SLU8R
STLS4R
STRBR
TLA4R
TMGL4R
8SLAR
1
Identified at a traffic flow of 0.8 Erlang
D-10
Part Number
S30122-K7373-A900
S30122-K7373-M900
S30177-U773-X with
S30122-K7686-M1
Part Number
S30807-H5482-X
S30807-H5485-X
S30810-K2943-Z
S30122-K7379-Z100
S30807-Q5692-X100
S30810-K2956-X300
S30817-K922-Z301
S30817-K924-Z313
S30817-Q932-Z
S30817-Q923-Zxxx
S30810-K2918-Z
S30810-K2925-Z
Nur für den internen Gebrauch
Max. Nominal Output in W
5 V
1
20.0
Net Power Requirement in
5 V
7.0
10.0
2.6
2.0
0.8
1.0
0.5
0.2
1
5.7
1.3
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
–48 V
53.0
110
W
–48 V
2.0
3.0
0.5
0.3
1.4
5.0
1.0
1
0.1
1.3