inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
4.2.4.8

Connecting Cables and the Line Network

Not for U.S. and Canada: PB3000 connection cable (if present)
To meet EMC requirements, the braided shields on the connection cable must be connected
to the housing on both the HiPath 3500 or HiPath 3300 side and on the PB3000 side.
Attaching to the HiPath 3500 or HiPath 3300 side
Use a clip, a tooth lock washer, and a housing cover mounting screw to attach the braided
shield to the HiPath 3500 or HiPath 3300 housing (as shown in Figure 4-65). The tooth lock
washer must be mounted between the painted surface of the cover and the clip.
Figure 4-65
Attaching to the PB3000 side (see Section 9.1.3)
Line network
The connecting cords to the peripherals can be connected directly to the relevant MW8 jacks
on the front panel of the 19-inch housing.
Connecting the LAN cable for HXGR3
LAN cables are connected to HXGR3 boards in a HiPath 3500 or HiPath 3300 according to the
description in Section 3.3.4.
Electromagnetic shielding
To ensure sufficient electromagnetic shielding (according to EN 55022), a shielded LAN
cable must be used, or the LAN cable being used must already be shielded.
4-118
HiPath 3500 and HiPath 3300 - Connection Cable for PB3000
Nur für den internen Gebrauch
Housing cover mounting screw
Clip
Tooth lock washer
Housing cover
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation