boards.fm
Boards for HiPath 3000
Peripheral boards
Assigning both CAS cables
You can use one of the following two cables to connect network terminators (NT), multiplexers
(MUX), or modems to the TMCAS-2 card (15-pin sub-D jacks X909 and X910):
symmetrical line (120 ohms), length = 10 m
Table 3-150
15-pin Sub-D connector
Pin
9
1
15
8
Coaxial trunk (75 ohms), length = 10 m
Table 3-151
Wire
1
2
Figure 3-107
3-312
TMCAS-2 (for selected countries only) – Assignment of the CAS Cable
S30267-Z167-A100
TMCAS-2 (for selected countries only) – Assignment of the CAS Cable
C39195-A7700-B14
Function
Receive, Tip
Receive, Ring
Transmit, Tip
Transmit, Ring
15-pin Sub-D con-
nector
TMCAS-2 (for selected countries only) – CAS Cable C39195-A7700-B14
Function
a-wire (T), transmit
b-wire (R), transmit
a-wire (T), receive
b-wire (R), receive
15-pin Sub-D con-
nector
Pin
8
15
1
9
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Color code
wht/blu
blu/wht
wht/ora
ora/wht
BNC connector
Shield
Conductor
Shield
Conductor
BNC connector