Siemens HiPath 3000 Series Service Documentation page 1268

Table of Contents

Advertisement

power_calc.fm
Identifying System Power Requirements
Checking Whether the Output of a Power Supply Unit is Sufficient
2.
Determine secondary power requirement at the -48-V output
power requirements of the boards/
components used =
+
power requirement of connected
workpoint clients, key modules and
adapters =
=
secondary power requirement at the -
48-V output =
The maximum nominal output of UPSC-D at the -48-V output amounts to 53 W and is
enough to cover the specified power requirement.
D-16
0.50 W
1 x CBCC
2.80 W
1 x HXGS3 (including ventilator
kit)
0.00 W
1 x TS2N
0.00 W
3 x SLU8
1.30 W
1 x 8SLA
0.00 W
1 x SLC16N
24.00 W
12 x BS3/1
4.32 W
6 x optiPoint 500 advance
8.40 W
12 x optiPoint 500 basic
2.40 W
8 x optiPoint 500 entry
0.00 W
2 x Hicom Attendant BLF
0.00 W
2 x optiPoint BLF
0.40 W
8 x optiPoint key module
0.50 W
2 x optiPoint acoustic adapter
1.80 W
6 x analog telephones
47.83 W