service.fm
Service
Guided Maintenance
1.
Start the program.
2.
Via Capture -> Options, open the "Wireshark: Capture Options" window.
3.
In the "Interface:" selection and input field, enter the following:
rpcap://<IP address of the HG1500>/emac0
or:
rpcap://<IP address of the HG1500>/emac1
Only the HG 1500 data packets are monitored.
4.
In the "Capture Filter:" selection and input field, enter the following:
not host <IP address of the administrator PC>
The data packets of the administrator PC are excluded.
5.
Set additional settings as appropriate, see www.wireshark.org.
6.
Click Start to begin recording data packets. The data stream that comes from HG 1500 is
displayed.
3. Stopping monitoring
To stop monitoring, you must proceed in the following sequence in order to prevent HG 1500
from crashing:
1.
Stop Wireshark via Capture -> Stop.
2.
Stop the HG 1500 rpcap daemon:
1.
In the WBM via Maintenance -> Platform Diagnosis -> rpcap daemon, open the
"Stop rpcap daemon" window. Under "Client identification for access control", the HG
1500 IP address entered above is shown in the "IP address (numeric or literal):" field.
2.
Click Apply to stop the rpcap daemon. The HG 1500 server port is closed. Access, for
example, via Wireshark is no longer possible.
12-46
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation