Nur für den internen Gebrauch
9.1.3.2

Components

Powerbox PB3000 housing: S30177-U773-X
including assembly kit for 19-inch cabinet installation (C39165-A7027-D1)
Assembly kit for the wall attachment or desk installation of the PB3000 (optional):
C39165-A7027-D2.
Can be ordered as required with the following separate component:
LM/PHW: L30251-U600-A170, PST number: DUA170, "Wall bracket for HiPath 3300/3500
and Powerbox 3000"
Power supply cable (to be ordered separately):
EU:
Switzerland:
Britain:
Australia:
Euro:
Brasil:
4 x 12-V/7-Ah batteries: 4 x V39113-W5123-E891 (optional)
Power supply LUNA2: S30122-K7686-M1 (optional)
The LUNA2 has to be set to mode 2a to work probably with a Power Box PB3000. How to
set the LUNA2 mode, please refer to Section 3.2.12, "LUNA2".
Connection cable for PB3000, with batteries and LUNA2
Depending on the system, one of the following connection cables is used in addition to the
cable C39195-A7985-B38:
HiPath 3500, HiPath 3300: PB3000 is connected via connection cable C39195-A7985-
B24
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
C39195-Z7001-C11
C39195-Z7001-C38
C39195-Z7001-C32
C39195-Z7001-C57
C39195-Z7001-C46
For HiPath 3350 and 3550:
C39195-Z7001-C121 (IEC 60320 jack, straight)
For HiPath 3300, 3500 and 3800:
C39195-Z7001-C191 (IEC 60320 jack, 90° right-angled)
Expanding and Upgrading HiPath 3000
HiPath 3000Expanding
exup.fm