Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
21-008 !Clock OFF
21-011 !Fan Alarm ON
21-012 !Fan Alarm OFF
21-013 !no ack from
temp. sensor
21-014 !overload at code
receiver
21-015 !overload at code
transmit.
21-019 !Shorten Msg not
successful
21-028 !Power Alarm on
21-029 !Power Alarm off
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Meaning
ISDN clock lost.
Fan error.
The fan error has
been corrected.
No response from
temperature sen-
sor.
Not enough DTMF
receivers.
Not enough DTMF
transmitters.
Internal error: An
overlong ISDN
message could not
be shortened by
deleting Facility
IEs.
Emergency battery
operation due to
power outage.
Power supply re-
stored.
Required Measures
Check that the clock is
available on the S
/S
0
line.
If necessary, use HiPath
3000/5000 Manager E to
correct the clock's allowed/
denied numbers list (Trunk
– Clock parameters).
If necessary, perform a
hard restart (reset).
Check the fan and air sup-
ply in the 19" housing.
Note the ambient tempera-
ture.
None
Use a larger system.
Use a larger system.
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
Check line voltage.
Note battery capacity.
None
service.fm
Service
Guided Maintenance
Note
2M
12-81