Static Traffic Capacity

The static traffic capacity of the HiPath 3800 system can be determined as follows.
Table 4-5
HiPath 3800 - Static Traffic Capacity
HiPath 3800
Single-cabinet system
(see Page 4-46)
Two-cabinet system
(see Page 4-47)
1
The basic cabinet provides two PCM highway bundles with 2 x 4 PCM highways each. DIUT2, DIUN2, DIU2U (for U.S.
only), and STMI2 use the PCM highways from trunk group F. Thus there are an additional 128 time-division multiplex chan-
nels available for these boards in the basic cabinet for slots 1 – 5 and slots 7 – 10. If HiPath 3800 is used as a two-cabinet
system, the PCM highway trunk group F cannot be used.
4-50
Slots per PCM
segment
1 – 5
7 – 10
1 – 5
7 – 10
11 – 16
18 – 24
Static traffic capacity
per PCM segment
128 erlangs + (128 er-
1
langs
)
128 erlangs + (128
1
erlangs
)
128 erlangs
128 erlangs
128 erlangs
128 erlangs
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Total static traffic ca-
pacity of the system
512 erlangs