Siemens HiPath 3000 Series Service Documentation page 1257

Table of Contents

Advertisement

Nur für den internen Gebrauch
Table D-4
HiPath 3550 Board Power Requirement
Board or Component
SLAD8
1
SLAD16
SLC16N
SLMO24
SLU8
STLS2
STLS4
STRB
T
CAS-2
TLA2
TLA4
TLA8
TMAMF
TMCAS
TMGL4
TMQ4
TST1
TS2N
V24/1
4SLA
8SLA
16SLA
1
Detailed configuration rules are provided in section 3.3.12 SLAD16.
2
For each active (off hook) station, the net resource requirement increases by approximately 1.6W (dependent on the tele-
phone's line length and DC resistance).
3
Identified at a traffic flow of 0.8 Erlang
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Part Number
S30810-H2956-X200
S30810-Q2957-X
S30810-Q2193-X100
S30810-Q2901-X
S30817-Q922-A301
S30817-Q924-B313
S30817-Q924-A313
S30817-Q932-A
S30810-Q2945-X
S30817-Q923-Bxxx
S30817-Q923-Axxx
S30817-Q926-Axxx
S30810-Q2587-A400
S30810-Q2938-X
S30810-Q2918-X
S30810-Q2917-X
S30810-Q2919-X
S30810-Q2913-X300
S30807-Q6916-X100
S30810-Q2923-X200
S30810-Q2923-X100
S30810-Q2923-X
Identifying System Power Requirements
HiPath 3550 Board Power Requirement
Net Power Requirement in
Information not available
power_calc.fm
W
5 V
–48 V
2.0
1.0
2
2.5
1.5
5.0
1.5
0.8
0.6
1.0
0.5
4.5
0.1
0.2
0.4
3
3
1.8
16.9
3
3
4.7
0.1
3.8
0.8
0.9
0.3
0.7
0.7
1.3
1.3
2.5
2.5
D-5

Hide quick links:

Advertisement

Table of Contents
loading