Nur für den internen Gebrauch
The MSI board TLA8 with eight analog trunks for DP and DTMF signaling in HiPath 3550 and
HiPath 3350.
To GEE
module
T/R ports
MSI 1 - 4
to trunk
T/R ports
MSI 5- 8 to
trunk
To GEE
module
Figure 3-90
TLA8 (not for U.S.) - Interfaces (S30817-Q926-Axxx)
Table 3-121
TLA8 (not for U.S.) - Contact Assignments
Contact
Connector X3
1
2
3
4
5
6
7
8
9
10
GMZ= Call charging module assignment
GND= GND for GEE50 FKR, otherwise free
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
1
X3
10
1
X2
8
1
X4
8
1
X5
10
Connector X2
GND
b trunk 1
a trunk 1
b trunk 2
a trunk 2
b trunk 3
a trunk 3
b trunk 4
a trunk 4
GMZ 1
TLA8
Connector X4
a trunk 1
b trunk 1
a trunk 2
b trunk 2
a trunk 3
b trunk 3
a trunk 4
b trunk 4
Boards for HiPath 3000
Peripheral boards
50
To CUP/CUC
X1
2
Connector X5
a trunk 5
b trunk 5
a trunk 6
b trunk 6
a trunk 7
b trunk 7
a trunk 8
b trunk 8
boards.fm
GND
b trunk 5
a trunk 5
b trunk 6
a trunk 6
b trunk 7
a trunk 7
b trunk 8
a trunk 8
GMZ 2
3-259