The operating mode (short or long line with the appropriate flash times) can be set up for each
subscriber line interface with HiPath 3000/5000 Manager E (the menu settings: Set up station
–> Station –> Param –> Flags).
Technical connection conditions
Maximum supply current: approximately 34 mA; maximum supply voltage: approximately
40 V DC
Ring voltage against negative supply voltage (a-wire (tip)/RING): two telephones maxi-
mum
Range, see Section 2.7
Loop current detection > 10 mA
Ground button detection > 20 mA
The transmission technology is set according to the specific country through the respec-
tively entered country code (for country initialization, see Chapter 5, "Starting Up HiPath
3000").
3-350
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation