Service
Guided Maintenance
Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
Error Class 29 – Messages Concerning Board Communication
29-000 !error from COS-
MOS
29-010 !receive buffer not
free
29-014 !illegal pointer
29-024 !polling time out
29-025 !card ist present-
LW has reset it-
self
29-035 !ELIC deadlock
no Interrupt from
ELIC
Error Class 30 – Board Software Messages
30-006 !XCSEPBC: PBC
error
30-016 !HEATER ON -
HXG3
12-84
Meaning
COSMOS error.
Receive buffer is
not free.
Invalid pointer.
The specified
board has malfunc-
tioned.
Loadware of speci-
fied board restart-
ed.
ELIC clock supply
malfunction.
PBC or ELIC error
on the specified
board.
Temperature in Hi-
Path 3550/HiPath
3350 wall housing
is too high.
Required Measures
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
Set up a trace using infor-
mation from BLS.
Set up IOP trace.
If this error persists, check
the board and the slot.
If this error persists, check
the board and the slot.
Check clock supply.
Check central control
board.
Replace board.
Check the fan kit and the
air supply in the wall hous-
ing. Note the ambient tem-
perature.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Note
The board re-
ceive buffer can-
not receive mes-
sages from the
system (perfor-
mance prob-
lems).
Possible caus-
es:
Faulty clock
supply
Environmen-
tal influenc-
es
Faulty con-
trol board