Siemens HiPath 3000 Series Service Documentation page 432

Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Peripheral boards
Procedure for retrofitting a TMCAS board
Step
1.
Disconnect system from power supply and open system.
2.
Insert TS2N (HiPath 3550).
3.
HiPath 3550 (wall housing): Insert TMCAS in slot 10.
4.
Plug in TMS2/TS2N-TMCAS connection cable.
5.
Connect the NT to the system using the TMCAS cable.
6.
Close the system and connect it to the power supply.
7.
After the system has booted, both boards are entered in the system's database
(TMS2 or TS2N and TMCAS).
8.
If necessary, configure with HiPath 3000/5000 Manager E.
Possible problems:
TMCAS not entered in HiPath 3000/5000 Manager E
The TMCAS is displayed automatically after the generation/regeneration of the database
in a system with a correctly inserted and connected TMCAS-TMS2/TS2N combination.
Missing electrical connection between TMS2/TS2N and TMCAS
No TMCAS entry in the database. If a correctly configured database (with TMCAS insert-
ed offline) is then loaded into the system using generation/regeneration, the TMCAS con-
figured in HiPath 3000/5000 Manager E appears only in the SW configuration.
Incompatible board configuration
There is a correctly inserted TMCAS-TMS2/TS2N combination in the system. If there is
a different board entered in HiPath 3000/5000 Manager E in the HiPath 3550's large slot,
the generation is rejected.
3-300
Activity
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents